Наукова електронна бібліотека
періодичних видань НАН України

Sensitivity studies of beta-radiation detector based on small-crystalline scintillator ZnSe(Te)

Репозиторій DSpace/Manakin

Показати простий запис статті

dc.contributor.author Gavrylyuk, V.
dc.contributor.author Gal’chinetskyi, L.
dc.contributor.author Danshin, E.
dc.contributor.author Zelenskaya, O.
dc.contributor.author Katrunov, K.
dc.contributor.author Ryzhikov, V.
dc.contributor.author Starzhynskyi, N.
dc.contributor.author Chernikov, V.
dc.date.accessioned 2015-03-30T08:45:47Z
dc.date.available 2015-03-30T08:45:47Z
dc.date.issued 2001
dc.identifier.citation Sensitivity studies of beta-radiation detector based on small-crystalline scintillator ZnSe(Te) / V. Gavrylyuk, L. Gal’chinetskyi, E. Danshin, O. Zelenskaya, K. Katrunov, V. Ryzhikov, N. Starzhynskyi, V. Chernikov // Вопросы атомной науки и техники. — 2001. — № 3. — С. 167-170. — Бібліогр.: 4 назв. — англ. uk_UA
dc.identifier.issn 1562-6016
dc.identifier.other PACS numbers: 29.40.-n, 07.77
dc.identifier.uri http://dspace.nbuv.gov.ua/handle/123456789/79270
dc.description.abstract A new large area β-detector has been designed and studied. The design includes wedge-shaped light transducers. A composite material based on a small crystalline ZnSe(Te) was applied onto the wide surface of light transducer. This design ensures optimum light collection from the large sensitive surface onto the output window of a much smaller size. An experimental specimen has been prepared, which showed a β-sensitivity Cβ=5.5 cm². The spectrograms of a ⁹⁰Sr+⁹⁰Y β-source obtained with the specimen under study make it possible to evaluate the age of the source by the ratio of low- and high-energy regions of the spectrum. Other designs are proposed for application of large-area detectors possessing wedge-shaped light transducers as elements of assembled constructions for high efficiency detectors operating under flow conditions. uk_UA
dc.description.sponsorship Samples provided by V.Silin are gratefully acknowledged. This work is supported by the INTAS Grant No 99-01348. uk_UA
dc.language.iso en uk_UA
dc.publisher Національний науковий центр «Харківський фізико-технічний інститут» НАН України uk_UA
dc.relation.ispartof Вопросы атомной науки и техники
dc.title Sensitivity studies of beta-radiation detector based on small-crystalline scintillator ZnSe(Te) uk_UA
dc.title.alternative Исследование чувствительности детекторов β–излучения на основе мелкокристаллического сцинтиллятора ZnSe(Te) uk_UA
dc.type Article uk_UA
dc.status published earlier uk_UA


Файли у цій статті

Ця стаття з'являється у наступних колекціях

Показати простий запис статті