<item>
<title>Титульні сторінки та зміст</title>
<link>http://dspace.nbuv.gov.ua:80/handle/123456789/147978</link>
<description>Титульні сторінки та зміст
</description>
<pubDate>Fri, 01 Jan 2016 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://dspace.nbuv.gov.ua:80/handle/123456789/147978</guid>
<dc:date>2016-01-01T00:00:00Z</dc:date>
</item>
<item>
<title>Статистические процедуры при двухстороннем ограничении контролируемого параметра в процессе производства кабельно-проводниковой продукции</title>
<link>http://dspace.nbuv.gov.ua:80/handle/123456789/147267</link>
<description>Статистические процедуры при двухстороннем ограничении контролируемого параметра в процессе производства кабельно-проводниковой продукции
Голик, О.В.
Рассмотрены вопросы статистического контроля в процессе производства массовой кабельно-проводниковой продукции на примере эмальпроводов. Получены результаты непосредственного контроля диаметра эмальпровода с полиимидной двухслойной изоляцией в непрерывном технологическом цикле. Представлена контрольная карта максимальной вероятности выхода диаметра за пределы определенного диапазона; Розглянуті питання статистичного контролю у процесі виробництва масової кабельно-провідникової продукції на&#13;
прикладі емальпроводів. Отримані результати безпосереднього контролю діаметра емальдроту з поліімдною ізоляцією у неперервному технологічному циклі. Представлена контрольна карта максимальної ймовірності виходу діаметру&#13;
за межі визначеного діапазону; Purpose. To consider issues of statistical control in the process&#13;
of mass production of cable and wire products on the example of&#13;
enameled wire. To analyze the results of direct control of the&#13;
diameter of the wire in two-layer polyimide insulation in a&#13;
continuous technological cycle. To submit to the control map of&#13;
maximum probability of the exit diameter outside a specific&#13;
range. To analyze the conditions under which maximum&#13;
sensitivity of process control. Methodology. Study of the&#13;
sensitivity of the control map of maximum probability of the exit&#13;
option for regulatory of limit in the field deviations of the&#13;
centered parameter close to zero. The existence of stable trends&#13;
in the change of a controlled parameter can reduce the&#13;
sensitivity of punishment to instability of the process. Results. To&#13;
achieve maximum sensitivity of control of the technological&#13;
frontier should be selected on the basis of the achieved level of&#13;
the average value of the parameter and its statistical scattering.&#13;
Process boundaries must be changed in accordance with the&#13;
achieved level of the average value of the parameter and its&#13;
statistical scattering. Such a change may serve as a quantitative&#13;
indicator of trends in the increase or decrease in the reliability&#13;
of the technological system. Originality. In particular the tasks&#13;
of current control using engineering tolerances for controlled&#13;
parameter are impractical. Control on Pmax should be directed&#13;
to the exception of manufacturing, the parameters of which&#13;
extend beyond the technical tolerances. Practical value. The&#13;
exception is the manufacture of bulk cable products, the&#13;
parameters of which extend beyond the technical tolerances.
</description>
<pubDate>Fri, 01 Jan 2016 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://dspace.nbuv.gov.ua:80/handle/123456789/147267</guid>
<dc:date>2016-01-01T00:00:00Z</dc:date>
</item>
<item>
<title>Требования к приборам для проведения вертикального электрического зондирования грунта при диагностике состояния заземляющих устройств</title>
<link>http://dspace.nbuv.gov.ua:80/handle/123456789/147266</link>
<description>Требования к приборам для проведения вертикального электрического зондирования грунта при диагностике состояния заземляющих устройств
Руденко, С.С.
На основе анализа статистической базы данных по зондированию грунта и диагностики состояния заземляющего&#13;
устройства сформулированы требования и созданы рекомендации относительно выбора приборов для проведения&#13;
вертикального электрического зондирования в зависимости от класса напряжения энергообъекта и доверительной&#13;
вероятности. Доказана эффективность выбора приборов на основе оптимальных требований.; На основі аналізу статистичної бази даних з зондування ґрунту та діагностики стану заземлювального пристрою&#13;
сформульовано вимоги та створено рекомендації щодо вибору приладів для проведення вертикального електричного&#13;
зондування в залежності від класу напруги енергооб’єкту та довірчої ймовірності. Доведена ефективність вибору приладів на основі оптимальних вимог.; urpose. Creation the scientific requirements for technical characteristics of equipment for vertical electrical sounding based on&#13;
the electrophysical characteristics of the soil of energy objects&#13;
with the different voltage classes. Methodology. In work used&#13;
statistical methods for the analysis database of results the soil&#13;
sounding and for receiving distribution of largest size of the&#13;
grounding system. To determine the required range of measurement and permissible value of circuit resistance applied the&#13;
mathematical description of the electromagnetic field to calculate&#13;
the apparent resistivity of the soil and the Wenner method of calculating the resistance of a vertical electrode. Also, in work used&#13;
elements of probability theory to creation the stochastic correlation between device parameters and characteristics object of the&#13;
research. Results. In the paper found that in the most severe cases&#13;
(when the depth of sounding is the three maximal diagonal of&#13;
grounding) at 99% energy objects in Ukraine the lower limit of&#13;
resistance measurement for the respective classes of voltage must&#13;
be no more than 1.3 milliohms to 35 kV, 0.6 mOhm to 110 kV, 0.5&#13;
milliohms to 150 kV, 0.1 mOhm for ≥ 220 kV. Also it proved that&#13;
the measurement equipment for vertical electrical sounding when&#13;
performing electromagnetic diagnostics of grounding system the&#13;
power facilities Ukraine with 35-750 kV voltage class for all possible values of soil resistivity should be with limit of measurement&#13;
from 0.1 mOhm to 7.2 kOhm and resistance measuring circuit to&#13;
66 kOhm. Originality.For the first time used a statistical approach to evaluate the optimal technical requirements for equipment the soils resistivity when performing diagnostics of grounding systems energy objects of Ukraine. The results obtained in this&#13;
work, establish the probabilistic dependence of the technical&#13;
characteristics of measuring equipment from the actual depth of&#13;
sounding in Wenners configuration (the distance between electrodes) and from the voltage class of object. Practical value. The&#13;
obtained results allow depending on the specific parameters of the&#13;
object optimally select the equipment. This technique allows you&#13;
to create a range of equipments with optimal cost and overall&#13;
dimensions depending on the region (considering to a significant&#13;
spread of values of soil resistivity) and on the voltage class of&#13;
investigated object
</description>
<pubDate>Fri, 01 Jan 2016 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://dspace.nbuv.gov.ua:80/handle/123456789/147266</guid>
<dc:date>2016-01-01T00:00:00Z</dc:date>
</item>
<item>
<title>Контроль изоляции сетей низкого напряжения методами двух и трех отсчетов вольтметра</title>
<link>http://dspace.nbuv.gov.ua:80/handle/123456789/147265</link>
<description>Контроль изоляции сетей низкого напряжения методами двух и трех отсчетов вольтметра
Olszowiec, P.
Представлено применение методов контроля изоляции сетей низкого напряжения постоянного и двойного рода тока&#13;
с помощью вольтметра и резистора. Приведены формулы для вычисления сопротивления изоляции методами двух и&#13;
трех отсчетов вольтметра. Предложен новый способ двух отсчетов вольтметра для сетей двойного рода тока.&#13;
Представлена модификация рассматриваемых методов, ограничивающая их основной недостаток – длительность&#13;
переходного процесса.; Представлено застосування методів контролю ізоляції мереж низької напруги постійного і подвійного роду струму за&#13;
допомогою вольтметра і резистора. Наведено формули для обчислення опору ізоляції методами двох і трьох відліків&#13;
вольтметра. Запропоновано новий спосіб двох відліків вольтметра для мереж подвійного роду струму. Представлена&#13;
модифікація розглянутих методів, що обмежує їх основний недолік – тривалість перехідного процесу; Purpose. In the paper there are described methods of two and three&#13;
voltmeter readouts for insulation resistance periodic measurement&#13;
in live DC and AC/DC IT networks. A new measuring method for&#13;
AC/DC networks is proposed. Application of a novel algorithm for&#13;
shortening of measurement cycle is explained. Methodology. All&#13;
methods of two and three voltmeter readouts consist in connection&#13;
of a resistor and measurement of mean value of network’s fixed&#13;
point-to-ground voltages. Results. A new algorithm implemented in&#13;
KDZ-3 device enables determination of steady-state voltage of a DC&#13;
network’s pole much faster than in other exploited systems. Originality. In author’s modification of two voltmeter readouts method,&#13;
line-to-ground voltage mean value is measured at AC side of&#13;
AC/DC network. This innovation has not been applied for implementation of periodic insulation monitoring in AC/DC IT networks&#13;
yet. Practical value. The use of author’s innovation will allow to&#13;
execute measurements at AC side of AC/DC IT networks which&#13;
might be necessary if rectifier’s output circuits are unavailable.&#13;
Shortening of measurement cycle duration of two or three voltmeter&#13;
readouts method’s is of great importance in networks with high&#13;
capacitance.
</description>
<pubDate>Fri, 01 Jan 2016 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://dspace.nbuv.gov.ua:80/handle/123456789/147265</guid>
<dc:date>2016-01-01T00:00:00Z</dc:date>
</item>