<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
<channel>
<title>Електротехніка і електромеханіка, 2015, № 5</title>
<link>http://dspace.nbuv.gov.ua:80/handle/123456789/144104</link>
<description/>
<pubDate>Sun, 12 Apr 2026 20:48:55 GMT</pubDate>
<dc:date>2026-04-12T20:48:55Z</dc:date>
<image>
<title>Електротехніка і електромеханіка, 2015, № 5</title>
<url>http://dspace.nbuv.gov.ua:80/bitstream/id/474594/</url>
<link>http://dspace.nbuv.gov.ua:80/handle/123456789/144104</link>
</image>
<item>
<title>Болюх Володимир Федорович (до 60-річчя з дня народження)</title>
<link>http://dspace.nbuv.gov.ua:80/handle/123456789/149381</link>
<description>Болюх Володимир Федорович (до 60-річчя з дня народження)
</description>
<pubDate>Thu, 01 Jan 2015 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://dspace.nbuv.gov.ua:80/handle/123456789/149381</guid>
<dc:date>2015-01-01T00:00:00Z</dc:date>
</item>
<item>
<title>Military and political aspects of one of the problems of the modern power industry</title>
<link>http://dspace.nbuv.gov.ua:80/handle/123456789/149380</link>
<description>Military and political aspects of one of the problems of the modern power industry
Gurevich, V.
The problem of Intentional Destructive Electromagnetic Impacts (IDEI) on power systems has become recently more and more&#13;
actual in connection with two modern trends: the extension of using microelectronics and microprocessor-based devices and systems in electric power industry – on the one hand, and the intensive design of special equipment for distance destruction of electronic devices and systems – with another. The most powerful method for such destruction is the High-altitude Electromagnetic&#13;
Pulse (HEMP) as a result of a high-altitude nuclear explosion. The history of experimental high-altitude nuclear explosions has&#13;
been known now for over half a century. During this time quite a few scientific articles and books presenting details of this phenomenon and measures of protection from it have been published. In view of this fact, it would be possible to assume that the&#13;
problem of protection against HEMP has been solved for a long time and modern power systems are well protected from this phenomenon. However the research performed by the author displays that actually it has not and for the past decades in one country&#13;
of the world, at least, no practical measures have been taken for the protection of the national infrastructures against HEMP and&#13;
all action has been restricted only to writing reports, recommendations and guidelines. In the paper the reasons for such situation&#13;
(in particular, political and military aspects of the problem) are analyzed.; Проблема преднамеренных дистанционных деструктивных воздействий (ПДДВ) на энергетические системы становится в последнее время все более и более актуальной в связи с двумя современными тенденциями: расширением использования микроэлектроники и устройств на основе микропроцессоров в электроэнергетике – с одной стороны, и&#13;
успехами, достигнутыми в разработке специальных видов оружия, предназначенных для дистанционного поражения&#13;
электронных устройств – с другой. Самый мощный метод дистанционного поражения электроники – электромагнитный импульс высотного ядерного взрыва (ЭМИ ЯВ). История экспериментальных высотных ядерных взрывов насчитывает половину столетия. За это время было опубликовано множество научных статей, книг, отчетов, подробно описывающих все детали этого процесса и меры защиты от него. В связи с этим, можно было бы предположить, что проблема защиты от ЭМИ ЯВ была за эти десятилетия успешно решена и современные электроэнергетические системы хорошо защищены от этого явления. Однако, исследование, выполненное автором, показывает,&#13;
что ни в одной стране мира до сих пор не были предприняты никакие практические меры защиты национальных&#13;
инфраструктур от ЭМИ ЯВ и все действия были ограничены только докладами, отчетами, рекомендациями. В данной статье проанализированы причины такой ситуации (в частности, политические и военные аспекты проблемы).
</description>
<pubDate>Thu, 01 Jan 2015 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://dspace.nbuv.gov.ua:80/handle/123456789/149380</guid>
<dc:date>2015-01-01T00:00:00Z</dc:date>
</item>
<item>
<title>Абсорбционные характеристики фазной и поясной бумажно-пропитанной изоляции силовых кабелей на постоянном напряжении</title>
<link>http://dspace.nbuv.gov.ua:80/handle/123456789/149379</link>
<description>Абсорбционные характеристики фазной и поясной бумажно-пропитанной изоляции силовых кабелей на постоянном напряжении
Беспрозванных, А.В.; Москвитин, Е.С.; Кессаев, А.Г.
Представлена методика определения индивидуальных характеристик фазной и поясной бумажно-пропитанной изоляции силовых кабелей среднего напряжения. Методика реализована на применении схемы замещения трехжильного&#13;
кабеля в общей металлической оболочке и анализе результатов совокупных измерений абсорбционных характеристик. Система линейных алгебраических уравнений для определения характеристик фазной и поясной изоляции является хорошо обусловленной. Решение системы линейных алгебраических уравнений сводится к суммированию результатов совокупных измерений с весовыми коэффициентами 6/14 и 1/14. Приведены результаты определения абсорбционных характеристик фазной и поясной изоляции силового кабеля на напряжение 6 кВ.; Представлено методику визначення індивідуальних характеристик фазної та поясної паперово-просоченої ізоляції&#13;
силових кабелів середньої напруги. Методика реалізована на застосуванні схеми заміщення трьохжильного кабелю в&#13;
загальній металевій оболонці та аналізі результатів сукупних вимірювань абсорбційних характеристик. Система&#13;
лінійних алгебраїчних рівнянь для визначення характеристик фазної та поясної ізоляції є добре обумовленою. Рішення&#13;
системи лінійних алгебраїчних рівнянь зводиться до сумування результатів сукупних вимірювань з ваговими коефіцієнтами 6/14 та 1/14. Наведено результати визначення абсорбційних характеристик фазної та поясної ізоляції силового кабелю на напругу 6 кВ.; Introduction. The moral and physical deterioration of medium&#13;
voltage power cables with phase and zone paper-impregnated&#13;
insulation requires implementation of quality systems and reliable nondestructive electric diagnostic. Informative indicator of&#13;
the insulation is the time decay curve of the charging current. It&#13;
reflects the processes of accumulation of space charges (absorption). The measurements are carried out the 15th since the second direct voltage supply, then – on the 30th and the second on&#13;
the 60th second. The ratio of the parameters measured in these&#13;
times gives the dimensionless criteria – absorption coefficients.&#13;
Three measurements are made at different times, provide a more&#13;
complete picture of the state of insulation than the measurement&#13;
of the value of steady leakage (conduction-through), adopted in&#13;
conventional prevention trials. Purpose. Research and testing&#13;
methods of diagnostics of power cables with paper-impregnated&#13;
insulation by absorption and phase characteristics of the belt&#13;
insulation based on the total measurements. Methodology. A&#13;
procedure for determining the individual characteristics of&#13;
phase and zone paper-impregnated insulation based realized on&#13;
the use of the equivalent circuit of a three-core cable in the&#13;
metal shell and solved of an over determined system of linear&#13;
algebraic equations by least squares. Results. The proposed&#13;
method allows determining the absorption characteristics of the&#13;
individual phase and zone insulation medium voltage power&#13;
cables in the overall metal shell at a direct voltage. Individual&#13;
characteristics reflect the characteristics of cables and allow a&#13;
greater degree to assess the degree of aging of each of the components of paper-impregnated insulation. Originality. Regardless of the cable connection diagrams probing electric field&#13;
grabs as the phase, and zone insulation. The cumulative nature&#13;
of the measurement leads to the fact that the differences in the&#13;
properties of insulation components are smoothed: the aggregate results of the measurements do not differ for the different&#13;
schemes of the same type. The individual characteristics of isolation, defined on the basis of the proposed method are more&#13;
differences than total, indicating that non-symmetrical modes of&#13;
operation of the cable. Practical value. The values of individual&#13;
characteristics power cables 6 kV are 3 times more total, because of what their direct measurement may be a problem. The&#13;
total resistance of several insulation spaces connected in parallel, behind the individual. Smaller values of insulation resistance are measured more easily, especially on short samples&#13;
cables.
</description>
<pubDate>Thu, 01 Jan 2015 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://dspace.nbuv.gov.ua:80/handle/123456789/149379</guid>
<dc:date>2015-01-01T00:00:00Z</dc:date>
</item>
<item>
<title>Удосконалення системи управління "динамічних конденсаторів" для компенсації реактивної потужності</title>
<link>http://dspace.nbuv.gov.ua:80/handle/123456789/149378</link>
<description>Удосконалення системи управління "динамічних конденсаторів" для компенсації реактивної потужності
Поднебенна, C.К.
Досліджено роботу «динамічних конденсаторів» для компенсації реактивної потужності. Запропоновано оригінальну&#13;
систему управління «динамічним конденсатором», яка забезпечує споживання ним близького до синусоїдального вхідного&#13;
струму. Це дозволяє зменшити вплив «динамічного конденсатору» на амплітудно-частотну характеристику мережі,&#13;
підвищити надійність його роботи та покращити точність компенсації реактивної потужності.; Исследована работа «динамических конденсаторов» для компенсации реактивной мощности. Предложена оригинальная система управления «динамическим конденсатором», которая обеспечивает потребление им близкого к синусоидальному входного тока. Это позволяет уменьшить влияние «динамического конденсатора» на амплитудночастотную характеристику сети, повысить надежность его работы и улучшить точность компенсации реактивной мощности.; Purpose. Modern approaches of VAR compensation are: using&#13;
compensators with stepped regulation, STATCOMs, active power filters. Recently, more attention is paid to VAR compensator’s&#13;
design based on the direct AC / AC converters, which are called&#13;
dynamic capacitors. Methodology. The dynamic capacitor (DCAP) is the capacitor bank, which is connected to the mains&#13;
through direct AC / AC buck converter. By varying the duty&#13;
cycle of bidirectional switches, smooth control of reactive power&#13;
can be achieved. However, in case of distorted mains voltage,&#13;
D-CAP mains current will have a high THD. This is due to the&#13;
fact that the D-CAP affects the frequency response of electric&#13;
grid thus leading to the appearance of resonances. With nonsinusoidal mains voltage, capacitors are affected by harmonics.&#13;
This reduces the reliability of the D-CAP, increasing the probability of their failure. To eliminate these drawbacks it is suggested to improve the D-CAP control system so that the input&#13;
current of the dynamic capacitor is forced to be close to sinusoidal. This can be achieved if the duty cycle of the switching bidirectional switches is changed according to the proposed expression. Results. The research is done on a single-phase DCAP with the proposed control system, its input current diagrams are shown. In contrast to the D-CAP with a constant duty&#13;
cycle control, the resulting THD of its input current is much&#13;
lower. Thus, the control system provides a form of the input&#13;
current that is close to a sine wave. This reduces the influence of&#13;
mains voltage harmonics on the D-CAP operation, increases its&#13;
reliability and improves power quality. Originality. The proposed D-CAP control system ensures reliable operation with&#13;
non-sinusoidal mains voltage. Practical value. Application of DCAPs with the proposed control system allows for improved&#13;
energy efficiency of electrical mains by providing VAR compensation and improving power quality.