<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
<channel>
<title>Електротехніка і електромеханіка, 2011, № 2</title>
<link>http://dspace.nbuv.gov.ua:80/handle/123456789/143422</link>
<description/>
<pubDate>Sat, 18 Apr 2026 11:34:06 GMT</pubDate>
<dc:date>2026-04-18T11:34:06Z</dc:date>
<image>
<title>Електротехніка і електромеханіка, 2011, № 2</title>
<url>http://dspace.nbuv.gov.ua:80/bitstream/id/427277/</url>
<link>http://dspace.nbuv.gov.ua:80/handle/123456789/143422</link>
</image>
<item>
<title>О пожарной безопасности электротехнических изделий</title>
<link>http://dspace.nbuv.gov.ua:80/handle/123456789/143474</link>
<description>О пожарной безопасности электротехнических изделий
Мясников, В.Е.
Standards on electrical products fire protection are analyzed. Comparative analysis of interpretation of the available standards requirements in the field of fire safety by Ukrainian specialists and by their Russian colleagues is made. Technically sound
</description>
<pubDate>Sat, 01 Jan 2011 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://dspace.nbuv.gov.ua:80/handle/123456789/143474</guid>
<dc:date>2011-01-01T00:00:00Z</dc:date>
</item>
<item>
<title>Диагностика кабельных линий энергосистем по тангенсу угла диэлектрических потерь и постоянной времени саморазряда бумажно-пропитанной изоляции</title>
<link>http://dspace.nbuv.gov.ua:80/handle/123456789/143473</link>
<description>Диагностика кабельных линий энергосистем по тангенсу угла диэлектрических потерь и постоянной времени саморазряда бумажно-пропитанной изоляции
Набока, Б.Г.; Беспрозванных, А.В.; Москвитин, Е.С.; Бутко, М.В.; Бутко, С.М.; Головань, А.А.
The paper suggests extending the experience of impregnatedpaper- insulated power cables technical condition maintenance to power supply system cables. Classification of cable line defects according to dielectric dissipation factor and impregnated-paper insulation self-discharge time constant is introduced. Results of technical diagnostics of power cable lines in operation are given.
</description>
<pubDate>Sat, 01 Jan 2011 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://dspace.nbuv.gov.ua:80/handle/123456789/143473</guid>
<dc:date>2011-01-01T00:00:00Z</dc:date>
</item>
<item>
<title>Об исключении сжатия цилиндрической оболочки после "среза" импульса внешнего магнитного поля</title>
<link>http://dspace.nbuv.gov.ua:80/handle/123456789/143472</link>
<description>Об исключении сжатия цилиндрической оболочки после "среза" импульса внешнего магнитного поля
Живанков, К.И.; Михайлов, В.М.
Furth’s idea of inductor shorting to prevent current oscillations after pulse shaving for avoidance of internal cylindrical conducting shell compression after the shell magnetic-impulse extension by negative pressure forces is theoretically verified. Feasibility of the shaving impulse frequency and magnitude increase along with negative pressure gain is also shown as compared with a scheme without inductor shorting.
</description>
<pubDate>Sat, 01 Jan 2011 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://dspace.nbuv.gov.ua:80/handle/123456789/143472</guid>
<dc:date>2011-01-01T00:00:00Z</dc:date>
</item>
<item>
<title>Цилиндрический виток конечной ширины с разрезом над идеально проводящим массивным проводником</title>
<link>http://dspace.nbuv.gov.ua:80/handle/123456789/143471</link>
<description>Цилиндрический виток конечной ширины с разрезом над идеально проводящим массивным проводником
Батыгин, Ю.В.; Гнатов, А.В.; Смирнов, Д.О.
In the article, a three-dimensional electrodynamic problem of eddy currents space-time distribution is solved, eddy currents excited by the field of an open final-width flat circular coil in a bulk conductor of high specific conductivity. Comparison of obtained results with analogs for an infinitely thin coil is made.
</description>
<pubDate>Sat, 01 Jan 2011 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://dspace.nbuv.gov.ua:80/handle/123456789/143471</guid>
<dc:date>2011-01-01T00:00:00Z</dc:date>
</item>
</channel>
</rss>
