<?xml version="1.0" encoding="UTF-8"?>
<feed xmlns="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/">
<title>Технічна електродинаміка, 2017, № 4</title>
<link href="http://dspace.nbuv.gov.ua:80/handle/123456789/158858" rel="alternate"/>
<subtitle/>
<id>http://dspace.nbuv.gov.ua:80/handle/123456789/158858</id>
<updated>2026-04-07T04:38:53Z</updated>
<dc:date>2026-04-07T04:38:53Z</dc:date>
<entry>
<title>Апаратно-програмний спосіб компенсації температурного дрейфа вихідного сигналу оптичного вимірювача концентрації метану</title>
<link href="http://dspace.nbuv.gov.ua:80/handle/123456789/158936" rel="alternate"/>
<author>
<name>Вовна, О.В.</name>
</author>
<author>
<name>Зорі, А.А.</name>
</author>
<author>
<name>Лактіонов, І.С.</name>
</author>
<id>http://dspace.nbuv.gov.ua:80/handle/123456789/158936</id>
<updated>2019-09-18T22:25:37Z</updated>
<published>2017-01-01T00:00:00Z</published>
<summary type="text">Апаратно-програмний спосіб компенсації температурного дрейфа вихідного сигналу оптичного вимірювача концентрації метану
Вовна, О.В.; Зорі, А.А.; Лактіонов, І.С.
Досліджено процеси у розробленому оптичному вимірювачі концентрації метану. Виявлено, що додаткова похибка вимірювання концентрації метану, обумовлена зміною температури від + 5 до + 35°С, у (64÷142) рази перевищує регламентовану основну похибку, яка становить +/-02об.%. Розроблено та реалізовано апаратно-програмний спосіб компенсації температурного дрейфа вихідного сигналу вимірювача концентрації метану. Як термочутливий елемент у вимірювачі використано світлодіод вимірювального каналу, а як інформаційний сигнал – падіння напруги на ньому. Реалізація запропонованого апаратно-програмного способу дозволила досягти величини додаткової похибки вимірювання концентрації метану від зміни температури не більше основної.; Исследованы процессы в разработанном оптическом измерителе концентрации метана. Определено, что дополнительная погрешность измерения концентрации метана, обусловленная изменением температуры от + 5 до + 35°С, в (64 ÷ 142) раза превышает регламентированную основную погрешность, которая составляет +/-0,2об.%. Разработан и реализован аппаратно-программный способ компенсации температурного дрейфа выходного сигнала измерителя концентрации метана. Как термочувствительный элемент в измерителе использован светодиод измерительного канала, а как информационный сигнал – падение напряжения на нем. Реализация предложенного аппаратно-программного способа позволила достичь величины дополнительной погрешности измерения концентрации метана от изменения температуры не более основной.; Processes in the developed optical methane concentration measurer are probed. It is determined that the additional error in measuring the methane concentration due to a change in temperature from + 5 to + 35ºС, in (64 ÷ 142) times exceeds the regulated main error, which makes ±0,2 vol.%. A hardware-software method of the output signal temperature drift compensating of the methane concentration meter has been developed and implemented. The LED of the measuring channel is used as a thermosensitive element in the measuring instrument, voltage drop on it is used as an information signal. Implementation of the proposed hardware-software method allowed to achieve the additional error magnitude of the methane concentration measuring from the temperature change, which doesn't exceed the basic one.
</summary>
<dc:date>2017-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Дослідження чутливості коефіцієнта ексцесу діагностичних сигналів для контролю стану електротехнічного обладнання</title>
<link href="http://dspace.nbuv.gov.ua:80/handle/123456789/158935" rel="alternate"/>
<author>
<name>Берегун, В.С.</name>
</author>
<author>
<name>Красильніков, О.І.</name>
</author>
<id>http://dspace.nbuv.gov.ua:80/handle/123456789/158935</id>
<updated>2019-09-18T22:25:33Z</updated>
<published>2017-01-01T00:00:00Z</published>
<summary type="text">Дослідження чутливості коефіцієнта ексцесу діагностичних сигналів для контролю стану електротехнічного обладнання
Берегун, В.С.; Красильніков, О.І.
Обґрунтовано доцільність використання коефіцієнта ексцесу діагностичних сигналів для розпізнавання двох станів об’єкта контролю. На прикладах типових симетричних розподілів підтверджена більша чутливість коефіцієнта ексцесу до відмінності розподілів діагностичних сигналів в порівнянні з інтегральною метрикою. Запропоновано алгоритм та виконано розрахунок мінімального об’єму вибірки діагностичного сигналу для оцінки коефіцієнта ексцесу, необхідного для виявлення дефектів в об’єкті, що діагностується. Проведено комп’ютерне моделювання реалізацій оцінок коефіцієнта ексцесу вібрацій підшипників кочення електричних машин. При проведенні моделювання як тестовий було використано розподіл Стьюдента при різних ступенях свободи, що підтвердило достовірність отриманих результатів.; Обоснована целесообразность использования коэффициента эксцесса диагностических сигналов для распознавания двух состояний объекта контроля. На примерах типичных симметричных распределений подтверждена большая чувствительность коэффициента эксцесса к отличию распределений диагностических сигналов в сравнении с интегральной метрикой. Предложен алгоритм и выполнен расчёт минимального объёма выборки диагностического сигнала для оценки коэффициента эксцесса, необходимого для обнаружения дефектов в диагностируемом объекте. Проведено компьютерное моделирование реализаций оценок коэффициента эксцесса вибраций подшипников качения электрических машин. При проведении моделирования в качестве тестового было использовано распределение Стьюдента при разных степенях свободы, что подтвердило достоверность полученных результатов.; Expediency of use of diagnostic signals excess kurtosis for recognition of two conditions of control object is proved. On examples of typical symmetric distributions bigger sensitivity of excess kurtosis to difference of diagnostic signals distributions in comparison with an integrated metrics is confirmed. An algorithm is proposed and the minimum sample size of the diagnostic signal is calculated to estimate the excess kurtosis required to detect defects in the diagnosed object. Computer simulation of the excess kurtosis realizations of vibration of rolling bearings of electric machines is carried out. When carrying out the simulation, Student distribution was used as a test with different degrees of freedom, which confirmed the reliability of the results obtained.
</summary>
<dc:date>2017-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Spectral method to evaluate the uncertainty of dynamic measurements</title>
<link href="http://dspace.nbuv.gov.ua:80/handle/123456789/158934" rel="alternate"/>
<author>
<name>Vasilevskyi, O.M.</name>
</author>
<author>
<name>Yakovlev, M.Yu.</name>
</author>
<author>
<name>Kulakov, P.I.</name>
</author>
<id>http://dspace.nbuv.gov.ua:80/handle/123456789/158934</id>
<updated>2019-09-18T22:25:36Z</updated>
<published>2017-01-01T00:00:00Z</published>
<summary type="text">Spectral method to evaluate the uncertainty of dynamic measurements
Vasilevskyi, O.M.; Yakovlev, M.Yu.; Kulakov, P.I.
Article suggested spectral method of assessing the measurement devices dynamic uncertainty that allows to investigate measurement accuracy in dynamic operating conditions in frequency domain and to estimate amplitude values of dynamic uncertainty based on input signal frequency characteristic and spectral function. The results were approbated when evaluating the engines vibration acceleration dynamic measurements uncertainty. It was established that maximum value of vibration acceleration dynamic measurement uncertainty amounts to 0.137 m/s² for observation time of 600 sec and vibration acceleration signal nominal value of 0.35 m/s² at a frequency of 6 kHz.; У статті запропоновано спектральний метод оцінювання динамічної невизначеності засобів вимірювань, який дозволяє досліджувати точність вимірювань у динамічному режимі роботи в частотній області, оцінювати амплітудні значення динамічної невизначеності на основі частотної характеристики та спектральної функції вхідного сигналу. Результати були апробовані під час оцінювання невизначеності динамічних вимірювань віброприскорення електродвигунів. Встановлено, що максимальне значення динамічної невизначеності вимірювання віброприскорення складає 0,137 м/c² при часі спостереження 600 с та номінальному значенні сигналу віброприскорення 0,35 м/c² на частоті 6 кГц.; В статье предложен спектральный метод оценки динамической неопределенности измерительных приборов, который позволяет исследовать точность измерений в динамических режимах эксплуатации в частотной области, оценивать амплитудные значения динамической неопределенности на основе частотной характеристики и спектральной функции входного сигнала. Результаты были апробированы при оценивании неопределенности динамических измерений виброускорения электродвигателей. Установлено, что максимальное значение динамической неопределенности измерения виброускорения составляет 0,137 м/c² при времени наблюдения 600 с и номинальном значении сигнала виброускорения 0,35 м/c² на частоте 6 кГц.
</summary>
<dc:date>2017-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Гармонический состав тока электромагнитного вибратора</title>
<link href="http://dspace.nbuv.gov.ua:80/handle/123456789/158933" rel="alternate"/>
<author>
<name>Черно, А.А.</name>
</author>
<id>http://dspace.nbuv.gov.ua:80/handle/123456789/158933</id>
<updated>2019-09-18T22:25:35Z</updated>
<published>2017-01-01T00:00:00Z</published>
<summary type="text">Гармонический состав тока электромагнитного вибратора
Черно, А.А.
Аналитически доказано, что частотный спектр тока электромагнитного вибратора включает в себя все нечетные гармоники и не содержит четных. Экспериментально установлено, что наибольшими по амплитуде являются первая и третья гармоники тока, а разность фаз между ними является монотонно убывающей функцией частоты в области резонанса. Это свойство можно использовать для управления частотой вибрационного привода.; Аналітично доведено, що частотний спектр струму електромагнітного вібратора включає в себе всі непарні гармоніки і не містить парних. Експериментально встановлено, що найбільшими за амплітудою є перша і третя гармоніки струму, а різниця фаз між ними є монотонно спадною функцією частоти в області резонансу. Цю властивість можна використовувати для керування частотою вібраційного привода.; The aim of the work is to study the current harmonic components of electromagnetic vibrator to make possible of its frequency control by using only current sensor signal. It was found analytically, that the current spectrum has all the odd harmonics and has not any even ones. Experimental investigations have also been performed. It was found, that the first and the third current harmonics have the highest amplitude. The phase difference between them is a monotonically decreasing function of frequency in the resonance region, so this property can be used to control the frequency of the electromagnetic vibratory drive.
</summary>
<dc:date>2017-01-01T00:00:00Z</dc:date>
</entry>
</feed>
