Перегляд за автором "Akimov, V.E."

Сортувати за: Порядок: Результатів:

  • Akimov, V.E.; Kazarezov, I.V.; Korepanov, A.A.; Frolov, A.R.; Tsyganov, A.V. (Вопросы атомной науки и техники, 2001)
    The electron beam source based on GS-34 valve cathode-grid unit with oxide cathode of 12 mm in diameter is described. Originally the high voltage DC source was used to supply the gun. The cathode emission characteristic ...
  • Akimov, V.E.; Kazarezov, I.V.; Korepanov, A.A. (Вопросы атомной науки и техники, 1999)
    A 200 kV DC power source on the base of a high-voltage cascade generator [1] is used for a power supply of the electron gun for the VEPP-5 complex preinjector. Advantages of the circuit with DC power supply are its relative ...
  • Akimov, V.E.; Kazarezov, I.V.; Korepanov, A.A. (Вопросы атомной науки и техники, 2004)
    This paper describes a new 200 kV pulse modulator for the VEPP-5 complex preinjector electron gun. The pulse former is based on the solid state IGBT-switch and the new high turn ratio pulse transformer (PT). New design allows ...
  • Akimov, V.E.; Bulatov, A.V.; Logatchev, P.V.; Kazarezov, I.V.; Korepanov, A.A.; Maljutin, D.A.; Starostenko, A.A. (Вопросы атомной науки и техники, 2006)
    An electron miniaccelerator on the basis of Tesla-transformer for nondestructive testing of charged particle beams with operating voltage 120…200 kV, half-wave duration 4 mks and diagnostic beam current within few mA is ...
  • Akimov, V.E.; Kazarezov, I.V.; Kuznetsov, G.I.; Tiunov, M.A. (Вопросы атомной науки и техники, 2004)
    The electron gun with a new electron-optical system to match project parameters of the VEPP-5 preinjector is described. The gun produces the current with 10 A amplitude, pulse duration 2...3 ns at half-height and electron ...
  • Akimov, V.E.; Bak, P.A.; Galimov, R.N.; Kazarezov, I.V.; Korepanov, A.A.; Kot, N.H. (Вопросы атомной науки и техники, 1999)
    The modulator based on PFN described above has been operated during several hundreds hours at a PFN charge voltage U=20 kV and repetition rate of 50 Hz. At present the klystron and modulator are used for RF power supply ...
  • Akimov, A.V.; Akimov, V.E.; Bak, P.A.; Kazarezov, I.V.; Kot, N.H.; Chupyra, A.G.; Rezakov, A.M.; Yudin, V.D. (Вопросы атомной науки и техники, 2001)
    In the complex VEPP-5 preinjector the klystrons are supplied by the modulators with a pulse power of 150 MW, a voltage of 47.5 kV, a primary current of 6.3 kA and a pulse duration of 3.5 ms. During the long time operation ...
  • Akimov, A.V.; Akimov, V.E.; Bak, P.A.; Kazarezov, I.V.; Korepanov, A.A.; Kulenko, Ya.V.; Ribitskaia, T.V.; Kuznetsov, G.I.; Pachkov, A.A.; Tiunov, M.A. (Вопросы атомной науки и техники, 2006)
    The modified pulsed electron beam source on voltage 200 kV and current 10 A with half-height pulse duration 2.5 ns and repetition rate 50 Hz is described. The source gun has been performed on the base of impregnated ...